AIMS Attachment A: AIMS Statement of Work
Page 108 of 130
1. The systems shall adhere to a Client / Server model. The end devices
shall be the clients to the primary/secondary servers. All information
shall be communicated between the server(s) and the clients via the
assigned Virtual Local Area Network (VLAN).
2. Network connectivity shall be via the assigned VLAN on the FLL PDS.
Network communications shall utilize TCP/IP network communications
protocol. The CONTRACTOR shall identify the network bandwidth
requirements such as 10 Mb, 100 Mb, or Gigabit Ethernet.
3. End device addressing shall be coordinated with the County.
4. Sufficient resiliency / redundancy and logic shall be provided to assure
that the availability objectives (refer to Performance Requirements,
Section 3.10.5) can be met without manual intervention. All major
system hardware components shall be designed so that there is not
any single point of failure that can cause operations to be disrupted.
5. The system shall synchronize the date and time on all devices. The
system servers shall receive a time synchronization signal from the
local area network using the Network Time Protocol (NTP)..
6. The systems shall use industry standard components. The systems
shall not contain any proprietary interfaces or components.
7. System components shall be independent and capable of co-existing
on the system to allow for an increased level of capacity. Modular
design and flexibility shall be provided for easy expansion of the
system without degradation to the system's performance.
C. Database
1. The requirements below apply to the portions of the AIMS that require
database features.
2. The provided database(s) shall be capable of supporting real time data
warehousing. The database(s) shall use a common relational
database to store all data. The database(s) shall be based on
accepted and recognized industry standards.
3. The database(s) shall be open database connectivity (ODBC)
compliant and support the simple object access protocol (SOAP).
4. Database Architecture: The database(s) shall meet the following
requirements:
i Provide read consistency (data seen by a statement is consistent
with respect to a single point-in-time)
ii Provide creation of a read-consistent set of data when a table is
being queried (read) and simultaneously updated (written)
Exhibit 3